SKU |
C9500-32C |
C9500-32QC |
C9500-48YC |
C9500-24YC |
C9500-12Q |
C9500-24Q |
C9500-40X |
C9500-16X |
Chassis with 2 power supplies and
built-in fan |
25.64 lb (11.63 kg) |
21.85 lb (9.91 kg) |
21.96 lb (9.96 kg) |
20.99 lb (9.52 kg) |
25.75 lb (11.68 kg) |
25.75 lb (11.68 kg) |
25.75 lb (11.68 kg) |
23.6 lb (10.7 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 21.2 in |
1.73 x 17.5 x 18.0 in |
1.73 x 17.5 x 18.0 in |
1.73 x 17.5 x 18.0 in |
1.73 x 17.5 x 21.52 in |
1.73 x 17.5 x 21.52 in |
1.73 x 17.5 x 21.52 in |
1.73 x 17.5 x 21.52 in |
Rack Units (RU) |
1 RU |
1 RU |
1 RU |
1 RU |
1 RU |
1 RU |
1 RU |
1 RU |
Input voltage |
90 to 264 VAC* |
90 to 264 VAC* |
90 to 264 VAC* |
90 to 264 VAC* |
90 to 264 VAC* |
90 to 264 VAC* |
90 to 264 VAC* |
90 to 264 VAC* |
Operating temperature |
32° to 104°F (0° to 40°C) up to altitude of 10,000
feet |
32° to 104°F (0° to 40°C) up to altitude of 10,000
feet |
32° to 104°F (0° to 40°C) up to altitude of 10,000
feet |
32° to 104°F (0° to 40°C) up to altitude of 10,000
feet |
32° to 104°F (0° to 40°C) up to altitude of 10,000
feet |
32° to 104°F (0° to 40°C) up to altitude of 10,000
feet |
32° to 104°F (0° to 40°C) up to altitude of 10,000
feet |
32° to 104°F (0° to 40°C) up to altitude of 10,000
feet |
Altitude |
Operation up to 10,000 feet at 40°C; up to 6,000
feet at 45°C |
Operation up to 10,000 feet at 40°C; up to 6,000
feet at 45°C |
Operation up to 10,000 feet at 40°C; up to 6,000
feet at 45°C |
Operation up to 10,000 feet at 40°C; up to 6,000
feet at 45°C |
Operation up to 10,000 feet at 40°C; up to 6,000
feet at 45°C |
Operation up to 10,000 feet at 40°C; up to 6,000
feet at 45°C |
Operation up to 10,000 feet at 40°C; up to 6,000
feet at 45°C |
Storage temperature |
-4° to 149°F (-20° to 65°C) |
-4° to 149°F (-20° to 65°C) |
-4° to 149°F (-20° to 65°C) |
-4° to 149°F (-20° to 65°C) |
-4° to 149°F (-20° to 65°C) |
-4° to 149°F (-20° to 65°C) |
-4° to 149°F (-20° to 65°C) |
-4° to 149°F (-20° to 65°C) |
Relative humidity operating and
nonoperating (noncondensing) |
- Ambient (noncondensing) operating: 5% to 90%
- Ambient (noncondensing) nonoperating and
storage: 5% to 95%
|
- Ambient (noncondensing) operating: 5% to 90%
- Ambient (noncondensing) nonoperating and
storage: 5% to 95%
|
- Ambient (noncondensing) operating: 5% to 90%
- Ambient (noncondensing) nonoperating and
storage: 5% to 95%
|
- Ambient (noncondensing) operating: 5% to 90%
- Ambient (noncondensing) nonoperating and
storage: 5% to 95%
|
- Ambient (noncondensing) operating: 5% to 90%
- Ambient (noncondensing) nonoperating and
storage: 5% to 95%
|
- Ambient (noncondensing) operating: 5% to 90%
- Ambient (noncondensing) nonoperating and
storage: 5% to 95%
|
- Ambient (noncondensing) operating: 5% to 90%
- Ambient (noncondensing) nonoperating and
storage: 5% to 95%
|
- Ambient (noncondensing) operating: 5% to 90%
- Ambient (noncondensing) nonoperating and
storage: 5% to 95%
|
NEBS criteria levels |
NEBS:
- ETSI 300-019
- Requirements are covered under GR-63-CORE
with some deviations
- SR-3580 NEBS level 3 (GR-63-CORE, to current
issue, GR-1089-CORE, to current issue)
|
NEBS:
- ETSI 300-019
- Requirements are covered under GR-63-CORE
with some deviations
- SR-3580 NEBS level 3 (GR-63-CORE, to current
issue, GR-1089-CORE, to current issue)
|
NEBS:
- ETSI 300-019
- Requirements are covered under GR-63-CORE
with some deviations
- SR-3580 NEBS level 3 (GR-63-CORE, to current
issue, GR-1089-CORE, to current issue)
|
NEBS:
- ETSI 300-019
- Requirements are covered under GR-63-CORE
with some deviations
- SR-3580 NEBS level 3 (GR-63-CORE, to current
issue, GR-1089-CORE, to current issue)
|
NEBS:
- ETSI 300-019
- Requirements are covered under GR-63-CORE
with some deviations
- SR-3580 NEBS level 3 (GR-63-CORE, to current
issue, GR-1089-CORE, to current issue)
|
NEBS:
- ETSI 300-019
- Requirements are covered under GR-63-CORE
with some deviations
- SR-3580 NEBS level 3 (GR-63-CORE, to current
issue, GR-1089-CORE, to current issue)
|
NEBS:
- ETSI 300-019
- Requirements are covered under GR-63-CORE
with some deviations
- SR-3580 NEBS level 3 (GR-63-CORE, to current
issue, GR-1089-CORE, to current issue)
|
NEBS:
- ETSI 300-019
- Requirements are covered under GR-63-CORE
with some deviations
- SR-3580 NEBS level 3 (GR-63-CORE, to current
issue, GR-1089-CORE, to current issue)
|